SFFECO Prime 227
SFFECO Prime Series fire extinguishing systems fight fires using HFC-227ea/FK-5-1-12. This extinguishing agent is particularly suitable for the protection of spaces with electronic and electrical equipment and offers an economical fire protection solution especially for small and medium-sized rooms.
The clean agent extinguishing agent reduces the heat of the fire and thus stops the combustion reaction. It is very efficient yet unaggressive at the same time.
The extinguishing agent is stored as a liquid and transforms into a gas only when it exits from the extinguishing nozzles. It therefore extinguishes, as a rule, even concealed fire sources instantaneously. The rapid extinguishing of a fire already in the nascent phase minimizes the fire damage and prevents long downtimes or business interruptions. Furthermore, unlike the case of water, foam or powder, secondary damage caused by the extinguishing agent itself is practically impossible. Clean agent is neither corrosive nor electrically conductive, leaves no residue and can easily be removed from the space concerned through ventilation.
Besides Furthermore, the comparatively small quantity required for use is stored in liquid form. This allows for extremely compact storage of the extinguishing agent. In addition, in the design concentration of clean agent does not present any health hazard, which is why SFFECO Prime Systems installations are also suitable for areas that are accessed by people.
Advance Technology
50 bar technology
In addition to the operating pressures of conventional clean agent fire extinguishing systems of 25 bar and 42 bar, SFFECO Prime Series Extinguishing Systems are available in a 50 bar configuration, which offers some significant advantages. For example, they can be adapted individually and tailored specifically to the requirements of the protected area.
Longer Pipe Lines
The regulations for fire extinguishing systems using clean agent require that the protected area be flooded within a maximum of 10 seconds. The 50 bar technology makes it possible to use longer and more complex piping than systems using lower operating pressures. This means that the extinguishing agent can also be stored outside the protected area.
Benefits of using SFFECO Prime Extinguishing System
- The systems provide an excellent extinguishing effect in rooms with electronic and electrical equipment.
- The SFFECO Prime extinguishing system agent is also very suitable for zones that are frequented by people and has no ozone depletion potential.
- Operating pressures up to 50 bar allow for more extensive pipework and storage of the extinguishing agent outside the protected area.
- Through cost-effective multi-zone systems, a single stock of extinguishing agent is sufficient to cover several zones.
- The software calculates complex, asymmetrical pipe work automatically and delivers optimal solutions – both from a safety related and an economic perspective.
Benefits of HFC227ea
SFFECO Prime 227 Fire Extinguishing Systems fight fires using HFC-227ea. HFC-227ea is suitable for Class A, B, C fires and it is superior to water and dry chemical fire extinguishing agents. It is active on fire with complete extinguishment capability designed to fully discharge within seconds. HFC-227ea is Hepta Fluoropropane (CF3CHFCF3). It is liquefied compressed colorless, odorless, electrically non-conductive gas, works to quench fires in seconds and holds damage to a max.
This extinguishing agent is particularly suitable for the protection of spaces with electronic and electrical equipment and offers an economical fire protection solution especially for small and medium-sized rooms. The system can be used even if people are present in the premises. The HFC-227ea extinguishing agent reduces the heat of the fire and thus stops the combustion reaction. It is very efficient yet unaggressive at the same time.
Key Value Highlights:
- Suitable for Class A, B, and C fires
- Rapid total discharge within seconds
- Clean agent, no residue
- Colorless, odorless, electrically non-conductive
- Suitable for occupied spaces
- Efficient and non-aggressive fire suppression
Single Zone System
SFFECO Prime Series Fire Extinguishing Systems can be designed for use as a SINGLE-ZONE SYSTEM to protect a single protected area or in the form of a MULTI-ZONE SYSTEM to protect two or more areas.
Multi Zone System
Multi zone system helps to save space & investment cost and it is easy extendable at any time. With 50 bar technology, it is possible to set up one multi-zone system instead of several single-zone systems. Multi-zone systems make use of a common, single stock of extinguishing agent for all rooms while, in the case of single-zone systems, a separate storage facility must be provided for each room. As such, multi-zone systems reduce costs and save space.
Multi zone systems are very similar to single zone systems, except that they use a common stock of extinguishing agent to protect all rooms.
In the event of a fire, the fire detection and control panel controls specific selector valves. These valves release the extinguishing agent only into the extinguishing zones affected by the fire.
The required quantity of extinguishing agent is always calculated in relation to the largest protected space.
The pneumatic control system will only supply the agent required to hazards affected. With the connected reserve of extinguishing agent, the fire extinguishing capacity of the system is guaranteed even after the extinguishing system has been triggered – providing continuous, uninterrupted operation.
How the System Works?
System Discharge Live Test
Certifications
SFFECO Prime Clean Agent Fire Extinguishing Systems are certified by UL Laboratories and FM Approved, ensuring full compliance with international safety and performance standards. The systems are manufactured under stringent quality control procedures, including rigorous inspection, testing, and validation at every stage of production. These comprehensive quality processes guarantee reliable performance, consistent product quality, and long-term system integrity in critical fire protection applications.